Three needs. Three solutions. Three platforms…Discover the Flexa Sensors ecosystem!

Flexa Sensors. Weigh the moment

Why has Flexa Sensors developed three different systems?

The Real-Time, Internet of Things and NLP lines meet three different needs within the entertainment & exhibition sectors when it comes to suspended load monitoring

The IoT line is suitable for managing large networks with thousands of nodes that connect to the Cloud through one or more Gateways.
Data are updated approximately every 3 minutes. All information can be accessed by multiple devices connected to the Internet.

The Real-Time line is more suitable for managing up to a hundred of wireless cells. The system needs a local PC connected to a Gateway. Data are updated every second.

The LC-NLP line monitors the loads within a wired safety loop. The cable connection ensures constant control of the loads and an automatic reaction in case of anomalies, causing the immediate disconnection of the power supply to the hoists

Internet of Things Line

MAIN FEATURES
  • Data refresh period
    3 Minutes
  • Data management platform
    Cloud
  • Load Cell connection to Gateway
    Wireless
  • Gateway connection to platform
    Internet
  • Frequency
    868/915 MHz
  • Network protocol
    LoRaWAN®
  • Manual calibration of radio channels
    No
  • Internet connection required
    Yes
  • Concurrent data access from multiple devices
    Yes
  • Remote monitoring
    Yes
  • Max number of Cells per Gateway
    ≃300
  • Max number of Gateways per System
    ≃20
  • Max number of Repeaters per System
    --
  • Max number of Cells per System
    ≃1000
  • User friendly platform
    Yes
  • Drag & drop interface
    Yes
  • Management fees
    Yes
  • Active safety circuit (automatic e-stop)
    No

Real-Time Line

MAIN FEATURES
  • Data refresh period
    1 Second
  • Data management platform
    Local PC
  • Load Cell connection to Gateway
    Wireless
  • Gateway connection to platform
    USB Cable
  • Frequency
    868/915 MHz
  • Network protocol
    Proprietary
  • Manual calibration of radio channels
    No
  • Internet connection required
    No
  • Concurrent data access from multiple devices
    No
  • Remote monitoring
    No
  • Max number of Cells per Gateway
    ≃100
  • Max number of Gateways per System
    1
  • Max number of Repeaters per System
    2
  • Max number of Cells per System
    ≃100
  • User friendly platform
    Yes
  • Drag & drop interface
    Yes
  • Management fees
    No
  • Active safety circuit (automatic e-stop)
    No

LC-NLP Line

MAIN FEATURES
  • Data refresh period
    Instant
  • Data management platform
    LC-NLP 16 Module
  • Load Cell connection to Gateway
    XLR5 Cable
  • Gateway connection to platform
    Ethernet Cable
  • Frequency
    --
  • Network protocol
    Proprietary
  • Manual calibration of radio channels
    No
  • Internet connection required
    No
  • Concurrent data access from multiple devices
    No
  • Remote monitoring
    No
  • Max number of Cells per LC-NLP 16 Module
    16
  • Max number of LC-NLP 16 Module per System
    2
  • Max number of Repeaters per System
    --
  • Max number of Cells per System
    32
  • User friendly platform
    Yes
  • Drag & drop interface
    No
  • Management fees
    No
  • Active safety circuit (automatic e-stop)
    Yes